The following options appear in the Additional Settings portion of the Advanced page.

Other Settings Reference

The Other Settings field accepts a semicolon-separated list of name=value pairs. For example:
Keep the following in mind when you use this field:
  • Values cannot contain a semicolon (;) or an equals sign (=).
  • Setting names are listed in the following tables.
  • Some settings take effect immediately, and others require a restart of the application. The Restart column in each table indicates which settings require a restart. Contact CData Support at arcsupport@cdata.com to restart your instance after you change a setting that requires a restart.

Interface and Security

SettingDescriptionDefaultRestart
AllowUnmaskedPasswordsAllows administrators to reveal stored passwords in the UI. This works only over HTTPS and can be useful before an upgrade or migration. See the warning below for additional information.falseNo
ShowTransactionsTabAdds the Transactions tab, which is hidden by default, to the Activity page. When enabled, the Total Errors metric on the dashboard is also based on the transaction table. A restart is not required, but reload the page after you change the setting.falseNo
UseManagedSecurityAPIA process-wide switch that makes Arc use its embedded security provider for all cryptography. This is already enabled for HIPAA Arc Cloud tenants. This application-level setting is distinct from the connector-level CertUseManagedSecurityAPI setting. See the Common Errors section of the AS2 connector documentation for an example of when to use it.falseYes
When AllowUnmaskedPasswords is enabled, anyone with access to the settings can read stored passwords and other secrets. Enable it only for as long as you need it, and disable it afterward.

Database and Performance

SettingDescriptionDefaultRestart
AutomationIntervalThe pause, in milliseconds, between automation passes. A lower value polls more often but increases CPU and database load.500No
CommandTimeoutThe timeout, in seconds, for commands that Arc runs against its own application database. Increase it when cleanup, archive, or dashboard queries time out on a large database (for example, CommandTimeout=120). The setting partly takes effect without a restart, but best practice is to restart the application after making changes.

This is not the same as the CommandTimeout setting on the API connector, which controls queries that the connector runs against external systems.
60Partly

Cleanup and Retention

These settings control the daily cleanup task described on the Cleanup page.
SettingDescriptionDefaultRestart
ArchivePageSizeThe number of rows per query page when cleanup runs in Archive mode. Lower it if archiving has trouble on a large database. This applies only to Archive mode.10000No
AutoTaskTimeThe time of day when the daily cleanup task runs, in HH:mm 24-hour format (for example, 02:30). The time is interpreted in the server’s local time zone.00:00Yes
CleanupTransactionsChunkSizeThe number of rows that cleanup removes in each DELETE operation. Lower it to shorten database lock times.5000No
LegacyTransactionRollbackDaysThe number of days that Arc keeps the previous transaction table, app_transactions, after it migrates your transaction logs to the new table, app_transactions_v2. This is a one-time migration that happens only when you upgrade from an earlier release that uses app_transactions. After the migration, Arc keeps app_transactions for this number of days so that you can still roll back the upgrade, and then removes it.

Set this to 0 to keep app_transactions indefinitely. Values from 1 to 29 are raised to 30, and values greater than 30 are used as is. Only 0 keeps the table indefinitely. Setting it to -1, which some other settings accept, does not have the same effect.
30No
MaxAutomationLogsThe maximum number of automation log rows that cleanup keeps.100000No

Health Checks and Alerts

SettingDescriptionDefaultRestart
NotifyCertificateExpireDaysThe number of days before a certificate expires that Arc begins alerting about the expiration. This must be a whole number.30No
SysLogMessageFormatThe format of the syslog message payload: CEF, JSON, or StructuredData. This applies only when SysLogVersion=1 and syslog is enabled.CEFNo
SysLogVersionThe syslog protocol version. 0 uses RFC 3164 and 1 uses RFC 5424. You must set this to 1 to use SysLogMessageFormat. Configure syslog on the Alerts page.0No
Set SysLogVersion and SysLogMessageFormat together. For example, to send JSON payloads over RFC 5424:

AI

These settings apply to the built-in AI features, such as AI tasks and log and transaction analysis. See AI Settings for the related fields.
SettingDescriptionDefaultRestart
aicontextwindowThe context window size, in tokens. When empty, Arc uses the provider default, and Ollama falls back to 16384. This is primarily relevant when you run local models with Ollama. The AI connector also uses it when the connector does not override the global AI settings. Non-numeric values are ignored without a warning.EmptyNo
aitimeoutThe HTTP timeout, in seconds. Increase it for slow local models. This must be a whole number. Any other value causes AI task setup to fail. This setting does not apply to the AI connector, which has its own Timeout setting.600No

Automation Backoff

When a connector fails repeatedly, Arc can wait longer between automation runs. These three settings work together. After BackoffMinThreshold consecutive failures, a connector waits BackoffInterval minutes multiplied by (the number of failures past the threshold + 1) before its next run. The wait stops growing at BackoffInterval minutes multiplied by BackoffMaxThreshold. For details on how backoff is triggered and how a connector exits it, see Connector Backoff.
SettingDescriptionDefaultRestart
BackoffIntervalThe length of each backoff step, in minutes. A value of 0 or less turns backoff off.60No
BackoffMaxThresholdThe maximum number of backoff steps.15No
BackoffMinThresholdThe number of consecutive failures before a connector starts backing off.3No
With the default values, the first wait is 60 minutes and the longest wait is 15 hours. You can also set these values in the Other Settings field under Miscellaneous in Workspace Settings, and in the Other Settings field on a connector’s Advanced tab. The connector value takes precedence over the workspace value, and the workspace value takes precedence over the application value. The Validate connector never enters backoff.