In CData Arc, data travels through flows as Messages that consist of a body and metadata headers. For example, if one connector passes a file to another, the file is transmitted as a Message that contains the file in the body and metadata about the file and associated connectors as headers. Messages can be grouped together in Batch Groups, which allow multiple messages to travel together as a single unit. Some uses for Batch Groups include moving data between systems and processing multiple purchase orders at once. When a Message is part of a Batch Group, it is referred to as a Batch Message.
Key Capabilities
- Consolidates batch groups into a single unified message
- XPath-based merging for XML content with configurable output headers
- Flexible header handling (accumulate, keep same, or none)
Overview
The Batch Merge connector accepts a Batch Group that arrives in the Send folder (the Transactions tab of the connector settings pane) and merges the Batch Messages in the Batch Group into a single Message. The output Message passes down the flow through the Transactions tab, and it can be processed by other connectors as needed.Connector Configuration
This section contains all of the configurable connector properties.Settings Tab
Configuration
Settings that determine how the connector can be accessed.Advanced Tab
Logging
Settings that govern the creation and storage of logs.
| Setting | Description |
|---|---|
| Log Level | The verbosity of logs generated by the connector. When you request support, set this to Debug. |
| Log Subfolder Scheme | Instructs the connector to group files in the Logs folder according to the selected interval. The Weekly option (which is the default) instructs the connector to create a new subfolder each week and store all logs for the week in that folder. Leaving this setting blank tells the connector to save all logs directly in the Logs folder. For connectors that process many transactions, using subfolders helps keep logs organized and improves performance. |
| Log Messages | Check this to have the log entry for a processed file include a copy of the file itself. If you disable this, you might not be able to download a copy of the file from the Transactions tab. |
Other Settings
Miscellaneous
Miscellaneous settings are for specific use cases.
| Setting | Description |
|---|---|
| Other Settings | Enables you to configure hidden connector settings in a semicolon-separated list (for example, setting1=value1;setting2=value2). Normal connector use cases and functionality should not require the use of these settings. |
Automation Tab
Automation Settings
Performance
Settings related to the allocation of resources to the connector.
| Setting | Description |
|---|---|
| Max Workers | The maximum number of worker threads consumed from the threadpool to process files on this connector. If set, this overrides the default setting on the Performance Settings portion of the Advanced Settings page. |
| Max Files | The maximum number of files sent by each thread assigned to the connector. If set, this overrides the default setting on the Performance Settings portion of the Advanced Settings page. |