Key Capabilities
- RNIF 1.1 and 2.0 support for B2B document exchange
- Automatic message routing with per-partner configuration and flexible encryption/signing options
- Certificate-based security with synchronous/asynchronous acknowledgment handling
Overview
A RosettaNet connection is configured in two places. Configure the RosettaNet Profiles page with a local RosettaNet identifier, and private certificates. Then configure individual RosettaNet connectors with connection settings specific to a single trading partner. When an input file is processed by a RosettaNet connector, it is packaged and sent to the specified trading partner. When Arc receives a file over RosettaNet, it attempts to route the file to a specific RosettaNet connector. The application uses the RosettaNet identifiers in the RosettaNet message to determine which RosettaNet connector should receive the file. When a file is routed to a RosettaNet connector, that file is placed in the connector’s Transactions tab, or is passed along to the next connector in the flow.Profile Configuration
The RosettaNet Profile must be configured before connections can be established with individual RosettaNet connectors. Click Profiles on the navbar, then click the RosettaNet tab.RosettaNet Profile Tab
Personal Id
Settings for identifying the local profile.Personal Certificate
Settings related to the private decryption and signature certificate.Application URLs
Settings and displayed values related to accessing Arc from the public web.Miscellaneous
Miscellaneous settings are for specific use cases.
| Setting | Description |
|---|---|
| Other Settings | Enables you to configure hidden connector settings in a semicolon-separated list (for example, setting1=value1;setting2=value2). Normal connector use cases and functionality should not require the use of these settings. |
Connector Configuration
Once you configure the global RosettaNet profile settings, create and configure individual RosettaNet connectors for each trading partner on the Flows page.Settings Tab
Configuration
Settings for identifying and connecting to a specific RosettaNet trading partner.Connection Info
Settings related to connection parameters for the specified trading partner.Acknowledgments
Settings related to RosettaNet acknowledgments.Trading Partner Certificates
Settings related to the public key certificates provided by the trading partner.Advanced Tab
Alternate Local Profile
Settings that override the configuration on the Profiles page for this specific RosettaNet connector. Setting an alternate local profile lets you use different local certificates and identifiers for certain trading partners.TLS Client Authentication
Settings related to client authentication when two-way TLS authentication is required.HTTP Authentication
Settings related to HTTP client authentication.Advanced Settings
Settings not included in the previous categories.Proxy Settings
These are a collection of settings that identify and authenticate to the proxy through which the connection should be routed. By default, this section uses the global settings on the Proxy Settings portion of the Security Settings page. Clear the checkbox to supply settings specific to your connector.
| Setting | Description |
|---|---|
| Proxy Type | The protocol used by a proxy-based firewall. |
| Proxy Host | The name or IP address of a proxy-based firewall. |
| Proxy Port | The TCP port for a proxy-based firewall. |
| Proxy User | The user name to use to authenticate with a proxy-based firewall. |
| Proxy Password | A password used to authenticate to a proxy-based firewall. |
| Authentication Scheme | Leave the default None or choose from one of the following authentication schemes: Basic, Digest, Proprietary, or NTLM. |
Message
Message settings determine how the connector searches for messages and manages them after processing.
Note: The settings below are deprecated and hidden by default. They appear only on connectors where they were previously enabled or configured to a non-default value. To retain copies of successfully processed files, right-click the connector in the flow, choose Show Success Path, and connect the success path to a File connector.
| Setting | Description |
|---|---|
| Save to Sent Folder (Deprecated) | Copies files processed by the connector to the Sent folder. Disabled by default. Files saved to the Sent folder are not covered by Encryption at Rest. |
| Sent Folder Scheme (Deprecated) | Groups files in the Sent folder by the selected time interval. Only relevant when Save to Sent Folder is enabled. |
Logging
Settings that govern the creation and storage of logs.
| Setting | Description |
|---|---|
| Log Level | The verbosity of logs generated by the connector. When you request support, set this to Debug. |
| Log Subfolder Scheme | Instructs the connector to group files in the Logs folder according to the selected interval. The Weekly option (which is the default) instructs the connector to create a new subfolder each week and store all logs for the week in that folder. Leaving this setting blank tells the connector to save all logs directly in the Logs folder. For connectors that process many transactions, using subfolders helps keep logs organized and improves performance. |
| Log Messages | Check this to have the log entry for a processed file include a copy of the file itself. If you disable this, you might not be able to download a copy of the file from the Transactions tab. |
Miscellaneous
Miscellaneous settings are for specific use cases.
| Setting | Description |
|---|---|
| Other Settings | Enables you to configure hidden connector settings in a semicolon-separated list (for example, setting1=value1;setting2=value2). Normal connector use cases and functionality should not require the use of these settings. |
Automation Tab
Automation Settings
Settings related to the automatic processing of files by the connector.Performance
Settings related to the allocation of resources to the connector.
| Setting | Description |
|---|---|
| Max Workers | The maximum number of worker threads consumed from the threadpool to process files on this connector. If set, this overrides the default setting on the Performance Settings portion of the Advanced Settings page. |
| Max Files | The maximum number of files sent by each thread assigned to the connector. If set, this overrides the default setting on the Performance Settings portion of the Advanced Settings page. |
Alerts Tab
SLAs Tab
Establishing a Connection
Trading partners must provide some of the connection details that are required when you configure a new RosettaNet connector. At a minimum, these details should include:- Business Identifier
- Partner URL
- Partner Certificates
Business Identifier
Your trading partner is identified by their business identifier in a RosettaNet transaction. When sending outgoing requests, the business identifier is used in the header of the request to indicate the recipient. To establish a RosettaNet self-test, the identifier should be set to the same value as the Business Identifier on the Profiles page.Partner URL
The Partner URL is the endpoint where the trading partner receives RosettaNet transmissions. Outgoing RosettaNet messages are sent to this target endpoint, which must be unique for each trading partner. You can test the Partner URL with a web browser to check for networking or connectivity issues. To establish a RosettaNet self-test, the target URL should be identical or nearly identical to the Receiving URL on the Profiles page. You can replace the domain name from the Profiles page with the loopback address localhost to keep the RosettaNet transaction in the local network. An example local self-test URL ishttp://localhost:8001/pub/Receive.rsb.
If you do not replace the domain name with localhost, the RosettaNet message is routed outside of the local network. You can use this to check network configuration settings and to make sure that the message can reach Arc through any firewalls.